采集与人工录入对不上,八成不是采集误差,而是量具未校准、取值时点不同、单位与分辨率不一致这三类原因。三类差异最常见:量具超过校准周期,采集值本身已漂移;人工记录的是稳定后的读数,采集抓的是接触瞬间的峰值;量具分辨率与记录单位不一致,例如 0.001mm 被记成 0.01mm。简会建议做一周双录对照:同一检验项同时保留采集值与人工值,按工位统计偏差分布,再决定是校准、调整取值规则还是改记录单位。偏差判定阈值与双录周期,需质量部确认。